-
Part Number: SL-1651E-US
Brand: Anest Iwata
SL-1651E-US Oilless Scroll Pump
Estimated Lead Time:
5-7 days
Estimated Lead Time:
5-7 days
$7,412.40 -
Part Number: SL-165E-US
Brand: Anest Iwata
SL-165E-US Oilless Scroll Pump
Estimated Lead Time:
5-7 days
Estimated Lead Time:
5-7 days
$6,917.40 -
Part Number: SL-205-US
Brand: Anest Iwata
SL-205-US Oilless Scroll Pump
Estimated Lead Time:
5-7 days
Estimated Lead Time:
5-7 days
$13,363.20 -
Part Number: SL-2051-US
Brand: Anest Iwata
SL-2051-US Oilless Scroll Pump
Estimated Lead Time:
5-7 days
Estimated Lead Time:
5-7 days
$15,345.90 -
Part Number: SL-210-US
Brand: Anest Iwata
SL-210-US Oilless Scroll Pump
Estimated Lead Time:
5-7 days
Estimated Lead Time:
5-7 days
$13,741.20 -
Part Number: SS3
Brand: Ingersoll Rand
SS3 Bare Pump - 18002378
Estimated Lead Time:
2-3 Days
Estimated Lead Time:
2-3 Days
$809.99 -
Part Number: SS5
Brand: Ingersoll Rand
SS5 Bare Pump - 18002386
Estimated Lead Time:
2-3 Days
Estimated Lead Time:
2-3 Days
$1,059.99
Compare Bare Pumps
| Brand | Model | Type | Air Delivery (CFM) | Max Pressure (PSI) | Horsepower Range (HP) | CCN / Part Number |
|---|---|---|---|---|---|---|
| Ingersoll Rand | 15T | Two-Stage | 8–10 | 175 | 1.5–3 | — |
| Ingersoll Rand | SS3 | Single-Stage | 11.3 @ 90 PSI | 135 | 2–5 | 18002378 |
| Ingersoll Rand | SS5 | Single-Stage | 18 @ 90 PSI | 135 | 3–5 | 18002386 |
| Ingersoll Rand | 2340 | Two-Stage | 14 @ 175 PSI | 175 | 3–5 | 18002394 |
| Ingersoll Rand | 2475 | Two-Stage | 17–24 @ 175 PSI | 175 | 5–7.5 | 18002402 |
| Ingersoll Rand | 2475 (Gas) | Two-Stage Gas Drive | 24–27 @ 175 PSI | 175 | 8–13 (Gas HP) | 18002410 |
| Ingersoll Rand | 2545 | Two-Stage | 24–35 @ 175 PSI | 175 | 7.5–10 | 18002428 |
| Ingersoll Rand | 2545V | Two-Stage Vertical | 24–35 @ 175 PSI | 175 | 7.5–10 | 18002444 |
| Ingersoll Rand | 7100 | Two-Stage | 40–50 @ 175 PSI | 175 | 10–15 | 18002451 |
| Ingersoll Rand | 7100V | Two-Stage Vertical | 40–50 @ 175 PSI | 175 | 10–15 | 18002451 |
| Ingersoll Rand | 2000 | Two-Stage | 40–50 @ 175 PSI | 175 | 20–25 | 20102497 |
| Anest Iwata | SL-2101-US | Oil-Less Scroll | 8.3 @ 116 PSI | 116 | 2 | SL-2101-US |
| Anest Iwata | BRF110-10-J | Oil-Less Reciprocating Booster | 3.5 @ 145 PSI | 145 | 1 | BRF110-10-J |
Performance data shown are typical averages. Actual CFM may vary with drive speed, pulley ratio, and ambient temperature. For selection assistance or replacement guidance, contact Industrial Air Power.
Frequently Asked Questions
▶️ Question: What is a bare pump?
Answer: A bare pump is the core compressor assembly without a motor or tank. It’s used to replace the failed pump on an existing air compressor or as the foundation for a custom-built unit.
▶️ Question: Can I replace only the pump on my air compressor?
Answer: Yes. If your motor and tank are still in good condition, replacing just the bare pump restores performance and saves the cost of buying a complete compressor package.
▶️ Question: What’s the difference between oil-less and lubricated pumps?
Answer: Oil-less pumps, like those from Anest Iwata, deliver clean, oil-free air for sensitive applications, while lubricated two-stage pumps from Ingersoll Rand provide higher CFM and durability for industrial use.